Battery Needling and Extruding Machine
Application
1.Installation of lighting tube, outside the studio can clearly see the situation; needling / extrusion speed 10 ~ 80mm / s can be adjusted; - Needling / extrusion force value
250N ~ 13KN can be set to meet the requirements of different standards
2.Needling/Extruding force value 250N~13KN can be set arbitrarily to meet different standard requirements.
3.Wire coat metal fire pipe, effectively prevent the battery test process of ignition and combustion phenomena;
4.separation of control and test box with form, available at 1~2 meters operation, be safe.
5.Squeeze: The test cell is squeezed in two planes, and a squeezing pressure of about 13KN is applied through a vise or a hydraulic arm with a piston diameter of 32mm, the squeezing continues until it rises, and once the maximum pressure is reached, the squeezing is lifted.
6.Needling: The test shall be carried out at an ambient temperature of 20℃±5℃, the battery connected with a thermocouple (thermocouple contacts are fixed on the surface of the battery) is placed in a fume cupboard, and a non-corrosive rust-free steel needle with a diameter of 2-8mm is used to pierce the center of the largest surface of the battery at a speed of 10mm/s-40mm/s and held for an arbitrary period of time. center of the largest surface of the cell at a speed of 10mm/s-40mm/s and hold it for an arbitrary period of time.
 
		    
			 
		    
			 
		    
			Squeeze Indicator
| controllers | 7-inch touch screen | 
| Test area space | 250mm wide x 300mm deep | 
| Outer box size | Approx. 750*750*1800mm (W*D*H) subject to actual size | 
| drive method | motor drive | 
| Strength range | 1~20kN (adjustable) | 
| Force Measurement Accuracy | 0.1% | 
| unit conversion | kg, N ,lb | 
| Squeeze Stroke | 300mm | 
| Force value display | PLC touch screen display | 
| Battery Squeeze Head | Standard extrusion head, area ≥ 20cm². | 
| Inner box material | Stainless steel 1.5mm thick | 
| Outer case material | 1.2 mm thick A3 cold plate with lacquered finish | 
| safety device | The back side of the box is designed with air vent and pressure relief device 250*200mm, the box is equipped with lighting | 
| viewing window | 250x200mm two-layer vacuum toughened glass viewing window with explosion-proof grill | 
| exhaust vent | The back of the box is equipped with a high temperature exhaust fan and reserved exhaust pipe interface φ150mm. The exhaust fan will turn on and work immediately after the power is turned on. | 
| box door | Single door, left opening | 
| Box door switch | Open-on-disconnect threshold switch ensures no misuse and personnel safety. | 
| caster | Four universal castors underneath the machine for free movement. | 
Acupuncture Indicator
| steel needle | Φ3mm/φ5mm high-temperature resistant tungsten steel needle, length 100mm (can be specified) 2pcs each. | 
| Needle Stroke | 200mm | 
| unit conversion | Kg、N 、lb | 
| Needling speed | 10 ~40mm/s (adjustable) | 
| Needlepoint force value | 1~300Kg | 
| Force value display | PLC touch screen display | 
| drive method | Motor control, adjustable speed | 
Data Acquisition
| Voltage Acquisition | Voltage range: 0~100V | 
| Acquisition rate: 200ms | |
| Acquisition channel: 1 channel | |
| Accuracy: ±0.2%F.S (0~100V) | |
| temperature acquisition | Temperature range: 0℃~1000℃ K-type thermocouple | 
| Acquisition rate: 200ms | |
| Acquisition channel: 1 channel | |
| Accuracy: ±2℃ | 
 
				





 
			 
			 
			 
			 
			 
             
             
             
            